標題: | Simultaneous Determination of Antidiabetic Thiazolidinediones Using Flow Through Voltammetric Sensor |
作者: | Wang, Lai-Hao Song, Yan-Lin |
貢獻者: | 醫藥化學系 |
關鍵字: | Voltammetric sensor thiazolidine-2, 4-diones (TZDs) antidiabetic drugs |
日期: | 2014 |
上傳時間: | 2015-05-06 21:25:35 (UTC+8) |
出版者: | Bentham Science Publ Ltd |
摘要: | We developed a method that uses flow through voltammetric sensor to quantitatively determine thiazolidine-2, 4-diones (TZDs) derivatives which are pioglitazone, rosiglitazone and troglitazone. The method uses a gold electrode. The dynamic range for determining thiazolidine-2, 4-diones (TZDs) is extended by more than two orders of magnitude. The quantification limits are 0.10, 23, 15, 0.005 ng for thiazolidine-2, 4-dione, pioglitazone, rosiglitazone and troglitazone, respectively. The method can be applied to the quantitatively determining pioglitazone and rosiglitazone in antidiabetic drugs. Findings using high-performance liquid chromatography with a flow-through voltammetric detector and ultraviolet detector are comparable. |
關聯: | Current Pharmaceutical Analysis, v.10 n.4, pp.239-245 |
顯示於類別: | [食藥產業暨檢測科技系(含五專)] 期刊論文
|
文件中的檔案:
檔案 |
描述 |
大小 | 格式 | 瀏覽次數 |
index.html | | 0Kb | HTML | 2185 | 檢視/開啟 |
|
在CNU IR中所有的資料項目都受到原著作權保護.
|