Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/34928
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 18259/20457 (89%)
造訪人次 : 6430253      線上人數 : 443
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/34928


    標題: A graphene oxide/polyaniline nanocomposite biosensor: synthesis, characterization, and electrochemical detection of bilirubin
    作者: Ahmed, Noor sabah
    Hsu, Chou-Yi
    Mahmoud, Zaid H.
    Sayadi, Hamidreza
    Kianfar, Ehsan
    貢獻者: Univ Diyala, Coll Sci
    Chia Nan Univ Pharm & Sci, Dept Pharm
    Univ Diyala, Coll Sci, Chem Dept
    Fac Shahrood Branch, Dept Chem Engn, Shahrood Branch
    Islamic Azad Univ, Dept Chem Engn, Arak Branch
    Islamic Azad Univ, Gachsaran Branch, Young Researchers & Elite Club
    關鍵字: Sensitive Detection
    Oxide Nanosheets
    Membranes
    Serum
    Nanoparticles
    Separation
    Sensor
    日期: 2023
    上傳時間: 2024-12-25 11:05:47 (UTC+8)
    出版者: ROYAL SOC CHEMISTRY
    摘要: The level of free bilirubin is a considerable index for the characterization of jaundice-related diseases. Herein, a biosensor was fabricated via the immobilization of bilirubin oxidase (BOx) on graphene oxide (GO) and polyaniline (PANI) that were electrochemically co-precipitated on indium tin oxide (ITO) conductive glass. The structural enzyme electrode was characterized by FTIR, XRD, and Raman spectroscopy, while the spectral and thermal properties were investigated by UV-vis and thermogravimetric analysis (TGA). Owing to the activity of the fabricated BOx/GO@PANI/ITO biosensor, it could detect free bilirubin with good selectivity and sensitivity in a low response time. The electrochemical response was studied using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). At polarization potential 0.2 V vs. Ag/AgCl, the fabricated sensor illustrated a response in only 2 s at 30 degrees C and pH 7.5. The LOD and LOQ for the BOx/GO@PANI/ITO biosensor were calculated and found to be 0.15 nM and 2.8 nM, respectively. The electrochemical signal showed a linear response in the concentration range 0.01-250 mu M. At 5 degrees C, the biosensor demonstrated a half-time of 120 days, through which it could be utilized 100 times at this temperature conditions. By using a common colorimetric method, the data on bilirubin levels in serum showed a determination coefficient (R2) of 0.97. The level of free bilirubin is a considerable index for the characterization of jaundice-related diseases.
    關聯: Rsc Advances, v.13, n.51, pp.36280-36292
    顯示於類別:[藥學系(所)] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML46檢視/開啟


    在CNU IR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋