Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/29707
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 18034/20233 (89%)
造访人次 : 23618343      在线人数 : 841
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/29707


    標題: Differences between novel and conventional surveillance paradigms of ventilator-associated pneumonia
    作者: Chang, Hui-Chun
    Chen, Chin-Ming
    Kung, Shu-Chen
    Wang, Ching-Min
    Liu, Wei-Lun
    Lai, Chih-Cheng
    貢獻者: 休閒保健管理系
    關鍵字: Ventilator-associated event
    Diagnosis
    Definition
    日期: 2015-02
    上傳時間: 2016-04-19 19:05:21 (UTC+8)
    出版者: Mosby-Elsevier
    摘要: Objective: To investigate the concordance between novel and conventional surveillance paradigms for ventilator-associated pneumonia (VAP).
    Methods: This study was conducted at a regional teaching hospital in southern Taiwan with 5 acute intensive care units. To assess the validity of novel ventilator-associated event (VAE) surveillance, we retrospectively applied the VAE algorithm to analyze all VAP cases that were identified using conventional definitions between April 2010 and February 2014. Patient outcomes, including ventilator days, hospital stay lengths, and in-hospital mortality were recorded.
    Results: Among 165 episodes of conventional VAP, 55 (33.3%), 40 (24.2%), 20 (12.1%), and 2 (1.2%) episodes were classified as a ventilator-associated condition, an infection-related ventilator-associated complication, possible VAP, and probable VAP, respectively, according to the new VAE algorithm. Changes in positive end-expiratory pressure and inspired oxygen fraction levels during the development of VAP were significant higher among each VAE category than for conventional VAP (all P < .001). In-hospital mortality was significantly higher among patients with ventilator-associated condition than for patients with conventional VAP (P = .0185).
    Conclusions: In our study population, novel VAE surveillance only detected one-third of conventional VAP cases. Thus, more studies are needed to further validate VAE surveillance compared with conventional VAP by using strong microbiologic criteria, particularly bronchoalveolar lavage with a protected specimen brush for diagnosing VAP
    關聯: American Journal of Infection Control, v.43 n.2, pp.133-136
    显示于类别:[休閒保健管理系(所)] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML1621检视/开启


    在CNU IR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈