English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 18034/20233 (89%)
造訪人次 : 23369433      線上人數 : 499
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/22249


    標題: Removal of Monodisperse Liquid Aerosols by Using the Polysulfone Membrane Filters
    作者: Hsiao-Lin Huang
    Da-Ming Wang
    Se-Tsung Kao
    Shinhao Yang
    Yi-Chin Huang
    貢獻者: 職業安全衛生系
    關鍵字: Aerosol penetration
    Polysulfone membrane filters
    Face velocity
    Relative humidity
    Quality factor
    日期: 2007-03
    上傳時間: 2010-01-15 11:25:04 (UTC+8)
    摘要: Polymer membrane filters are extensively used for sampling and collecting aerosols. This work explores the aerosol penetration of the polysulfone (PSF) membrane filters using monodisperse liquid aerosols. Three concentration-casting polysulfone solutions (15, 20 and 25%) were utilized to yield PSF membrane filters with variously sized pores. Additionally, the effects of various factors, including the species of the aerosol (dioctyl phthalate and potassium chloride), the size of the aerosol (0.03–0.5 μm), the face velocity (5, 10 and 20 cm/s) and the relative humidity (30, 50 and 70%), on the aerosol penetrations, were estimated.
    Experimental results indicate that the penetrations of DOP liquid aerosols through 15, 20 and 25% PSF membrane filters with “Boltzmann charge equilibrium” are 3.1–9.1, 1.5–3.7 and 0.6–1.4%, respectively. The most penetrating size of the PSF membrane filters was around 0.05 μm. Our results further demonstrate that penetration through PSF membrane filters fell as the concentration-casting solution increased, because the pore size of the PSF membrane filters declines as the concentration of the casting solution rises. Moreover, the penetration of solid aerosols through PSF membrane filters exceeds that of liquid aerosols. Penetration through the PSF membrane filters increases obviously with the flow rate when aerosol smaller than 0.21 μm. When aerosol larger than 0.3 μm, the variations of penetration through the PSF membrane filters become smaller at different flow rates. The relative humidity does not influence the performance of the PSF membrane filters. Results of this study demonstrate that the 25% PSF membrane filter has a larger qF than the 15 and 20% PSF membrane filters.
    關聯: Separation and Purification Technology 54(1): p.96-103
    顯示於類別:[職業安全衛生系(含防災所)] 期刊論文