Loading...
|
Please use this identifier to cite or link to this item:
https://ir.cnu.edu.tw/handle/310902800/34567
|
Title: | Preoperative Apparent Diffusion Coefficient Values for Differentiation between Low and High Grade Meningiomas: An Updated Systematic Review and Meta-Analysis |
Authors: | Tsai, Yueh-Ting Hung, Kuo-Chuan Shih, Yun-Ju Lim, Sher-Wei Yang, Cheng-Chun Kuo, Yu-Ting Chen, Jeon-Hor Ko, Ching-Chung |
Contributors: | Chi Mei Hospital Department of Hospital and Health Care Administration, Chia Nan University of Pharmacy & Science Kaohsiung Medical University Kaohsiung Medical University Hospital University of California System University of California Irvine I Shou University E-Da Hospital Department of Health and Nutrition, Chia Nan University of Pharmacy & Science National Sun Yat Sen University |
Keywords: | atypical meningiomas histological-subtypes malignant meningiomas brain-tumors mri benign classification index |
Date: | 2022 |
Issue Date: | 2023-12-11 13:58:15 (UTC+8) |
Publisher: | MDPI |
Abstract: | The meta-analysis aimed to compare the preoperative apparent diffusion coefficient (ADC) values between low-grade meningiomas (LGMs) and high-grade meningiomas (HGMs). Medline, Cochrane, Scopus, and Embase databases were screened up to January 2022 for studies investigating the ADC values of meningiomas. The study endpoint was the reported ADC values for LGMs and HGMs. Further subgroup analyses between 1.5T and 3T MRI scanners, ADC threshold values, ADC in different histological LGMs, and correlation coefficients (r) between ADC and Ki-67 were also performed. The quality of studies was evaluated by the quality assessment of diagnostic accuracy studies (QUADAS-2). A chi 2-based test of homogeneity was performed using Cochran's Q statistic and inconsistency index (I-2). Twenty-five studies with a total of 1552 meningiomas (1102 LGMs and 450 HGMs) were included. The mean ADC values (x10(-3) mm(2)/s) were 0.92 and 0.79 for LGMs and HGMs, respectively. Compared with LGMs, significantly lower mean ADC values for HGMs were observed with a pooled difference of 0.13 (p < 0.00001). The results were consistent in both 1.5T and 3T MRI scanners. For ADC threshold values, pooled sensitivity of 69%, specificity of 82%, and AUC of 0.84 are obtained for differentiation between LGMs and HGMs. The mean ADC (x10(-3) mm(2)/s) in different histological LGMs ranged from 0.87 to 1.22. Correlation coefficients (r) of mean ADC and Ki-67 ranged from -0.29 to -0.61. Preoperative ADC values are a useful tool for differentiating between LGMs and HGMs. Results of this study provide valuable information for planning treatments in meningiomas. |
Relation: | DIAGNOSTICS, v.12, n.3, pp.630 |
Appears in Collections: | [Dept. of Hospital and Health (including master's program)] Periodical Articles [Dept. of Health and Nutrition (including master's program)] Periodical Articles
|
Files in This Item:
File |
Description |
Size | Format | |
diagnostics12030630.pdf | | 1899Kb | Adobe PDF | 104 | View/Open | index.html | | 0Kb | HTML | 353 | View/Open |
|
All items in CNU IR are protected by copyright, with all rights reserved.
|