English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 18074/20272 (89%)
造訪人次 : 4072995      線上人數 : 749
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/34526


    標題: Polybrominated Dibenzo-p-dioxins/Furans (PBDD/Fs) and Diphenyl Ethers (PBDEs) in the Indoor and Outdoor of Gymnasiums
    作者: Su, Ching-Kai
    Lu, Jian-He
    Chao, How-Ran
    Chang, Wei-Hsiang
    Tsai, Ming-Hsien
    Wang, Chih-Lung
    Lu, I-Cheng
    Chang, Yu-Ting
    Chuang, Hsiao-Chi
    Mansor, Wan-Nurdiyana-Wan
    Hsu, Yi-Chyun
    Tsai, Ying-, I
    Ma, Shang -Ming
    貢獻者: National Pingtung University Science & Technology
    Kaohsiung Veterans General Hospital
    National Pingtung University Science & Technology
    National Pingtung University Science & Technology
    Kaohsiung Medical University
    National Cheng Kung University
    National Pingtung University Science & Technology
    Cheng Shiu University
    Cheng Shiu University
    Taipei Medical University
    Universiti Malaysia Terengganu
    Kun Shan University
    Chia Nan University of Pharmacy & Science,Department of Environmental Engineering and Science
    National Pingtung University Science & Technology
    關鍵字: health-risk assessment
    flame retardants
    air-quality
    house-dust
    particulate
    pollution
    exposure
    exercise
    china
    日期: 2022
    上傳時間: 2023-12-11 13:55:49 (UTC+8)
    出版者: TAIWAN ASSOC AEROSOL RES-TAAR
    摘要: It is still unknown whether the organobromine compounds in the indoor environment of the gyms would affect human health. This study tried to investigate PM2.5 and indoor-dust levels of polybrominated dibenzo-p-dioxins/furans (PBDD/Fs) and diphenyl ethers (PBDEs) in the gyms and then to further assess the health risks of the gym users and employees who were exposed to these organobromines through inhalation and ingestion. The gyms were to be examined for PBDD/DF/DEs on PM2.5 indoors and outdoors and in indoor dust. The results showed that indoor -dust, indoor PM2.5, and outdoor PM2.5 levels of PBDD/Fs were 37.8 & PLUSMN; 13.7 pg WHO2005-TEQ g-1 and 0.00650 & PLUSMN; 0.00340 and 0.00469 & PLUSMN; 0.00101 pg WHO2005-TEQ m-3, respectively, in the gyms, while for PBDEs, they were 2670 & PLUSMN; 2330 ng g-1 and 9.54 & PLUSMN; 4.68, and 8.27 & PLUSMN; 3.46 pg m-3. The PBDEs levels observed in this study were relatively lower when compared with the current global data of PM2.5 and indoor dust levels of PBDEs. The observed PM2.5-bound PBDDFs and PBDEs in the indoor gyms were not related to those in the outdoor gyms, but certain PBDE level was associated with PBDD/Fs in the indoor dust of the gyms. It suggested that the outdoor emission might not be correlated with the indoor emission, whereas indoor-dust PBDD/Fs might be converted from the pyrolysis of indoor-dust PBDEs. To assess the risks, the non-dietary daily intakes of PBDEs and PBDD/Fs were estimated as 1.61-2.11 x 10-7 and 4.15-5.42 x 10-13 mg kg b.w.-1day-1, respectively, in the employees and 5.04-6.58 x 10-8 and 1.29-1.69 x 10-13 mg kg b.w.-1 day-1, respectively, in the gym users. The values didn't exceed the critical levels when the gym employees and users were assessed by non-cancer and cancer risks of organobromines. In conclusion, although the gym employees and users inhaled more PM2.5 during the exercise, the risks of PBDD/DE/DFs were still under the acceptable levels.
    關聯: Aerosol and Air Quality Research, v.22, Issue 9
    顯示於類別:[環境工程與科學系(所)] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    aaqr.220264.pdf814KbAdobe PDF123檢視/開啟
    index.html0KbHTML400檢視/開啟


    在CNU IR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋