English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 18074/20272 (89%)
造訪人次 : 4072127      線上人數 : 430
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/34419


    標題: Investigation and disinfection of bacteria and fungi in sports fitness center
    作者: Boonrattanakij, Nonglak
    Yomchinda, Sirikorn
    Lin, Fang-Jia
    Bellotindos, Luzvisminda M.
    Lu, Ming-Chun
    貢獻者: King Mongkuts Univ Technol Thonburi, Fac Engn, Dept Environm Engn
    Chia Nan Univ Pharm & Sci, Dept Environm Resources Management
    Univ San Carlos, Sch Engn, Talamban Campus
    Natl Chung Hsing Univ, Dept Environm Engn
    關鍵字: Fitness center
    Bioaerosols
    Disinfectant
    日期: 2021
    上傳時間: 2023-11-11 11:51:26 (UTC+8)
    出版者: SPRINGER HEIDELBERG
    摘要: This study investigated the air quality improvement in terms of bacterial and fungal contamination in an exercise room of a fitness center under normal operating conditions. Environmental conditions including air conditioning, ventilation, moisture, CO2, particulate matters, and total number of users were also recorded. In addition, fungal and bacterial load were assessed and disinfection on sports equipment surface was also examined. Background bacteria and fungi densities in bioaerosols were in the range of 249 +/- 65 to 812 +/- 111 CFU/m(3) and 226 +/- 39 to 837 +/- 838 CFU/m(3) in the exercise room of the fitness center and 370 +/- 86 to 953 +/- 136 CFU/m(3) and 465 +/- 108 to 1734 +/- 580 CFU/m(3) in the outdoor air, respectively. Chlorine dioxide and weak acid hypochlorous water aerosols could remove both bacteria and fungi much better than water scrubbing. Contact time of 15 min was sufficient to control both bacteria and fungi to comply with the official air quality standards. User density and carbon dioxide deteriorated both bacteria and fungi disinfection performance whereas temperature was only statistically significant on fungi disinfection. Other factors including relative humidity, airflow velocity, and particulate matters did not have any statistically significant effect on microbial inactivation. Apart from bioaerosol disinfection, inactivation of microorganisms on surfaces of sports equipment was also conducted using chlorine dioxide, zinc oxide, weak acid hypochlorous water, and commercial disinfectant. The surfaces of bicycle handle, dumbbell, and sit-up bench were found to be contaminated with bacteria. Overall bacterial load was 390 to 3720 CFU/cm(2) with Escherichia coli specifically 550 to 1080 CFU/cm(2). Chlorine dioxide and zinc oxide were noticeably better than weak acid hypochlorous water and commercial disinfectant in terms of bacteria inactivation whereas all tested disinfectants had comparable effectiveness on E. coli disinfection. Targeted microorganisms on the sports equipment surface were sufficiently inactivated within 2 min after the application of disinfectant.
    關聯: ENVIRON SCI POLLUT R, v.28, n.37, pp.52576-52586
    顯示於類別:[環境資源管理系(所)] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML247檢視/開啟
    s11356-021-14323-5.pdf1733KbAdobe PDF131檢視/開啟


    在CNU IR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋