    標題: Improvement of indoor air quality in pet shop using gaseous chlorine dioxide
    作者: Lu, Ming-Chun
    Huang, Da-Ji
    Hsu, Ching-Shan
    Liang, Chih-Kuo
    Chen, Geng-Min
    貢獻者: Chia Nan Univ Pharm & Sci, Dept Environm Resource Management
    Natl Taitung Jr Coll, Dept Elect Engn
    關鍵字: Pet shop
    Bioaerosols
    Gaseous chlorine dioxide
    Disinfection
    日期: 2018-07
    上傳時間: 2019-11-15 15:47:58 (UTC+8)
    出版者: SPRINGER
    摘要: Many studies have shown that pet shops have a high concentration of bioaerosols. Thus, effective disinfection protocols are essential to protect the pet shop staff and visitors to the store. The present study examines the effectiveness of gaseous chlorine dioxide (ClO2) fogging in minimizing the residual bacteria and fungi levels in a typical pet shop in Taiwan consisting of a commodity area, a lodging area, and a grooming area. This investigation uses three disinfection modes (DMs) according to different disinfection periods, namely once every hour (1DM), once every 2 h (2DM), and once every 3 h (3DM). The bacteria and fungi concentrations are measured before and after disinfection treatment, and the effectiveness of each disinfection mode is evaluated using standard statistical techniques. To assess the effect of the environmental factors on the disinfection efficiency, measurements are taken of temperature, relative humidity, airflow velocity, the carbon dioxide concentration, the PM1, PM2.5, PM7, PM10, and TSP level at each sampling locations. The results reveal that the effectiveness of the three disinfection modes depends on both the environmental parameters and the use of the three areas (e.g., commodity, lodging, or grooming). Hence, the choice of disinfection method should be adjusted accordingly. For all three disinfection modes, a faster air velocity is beneficial in spreading the disinfectant throughout the indoor space and improving the disinfection performance. Overall, the results presented in this study confirm that gaseous chlorine dioxide disinfection improves the air quality in the pet shop interior, and thus beneficial in safeguarding the health of the pet shop staff and visitors.
    link: http://dx.doi.org/10.1007/s10661-018-6723-2
    關聯: Journal of Immigrant and Minority Health, v.190, n.7, 371