Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/30489
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 18056/20254 (89%)
造访人次 : 496501      在线人数 : 605
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/30489


    標題: The Development of Quantitative Real-Time Detection of Flavors During Fermentation by fused-Droplet Electrospray lonization(FD-ESL) Mass Spectrometry
    作者: Chen, Chang-nan
    Lin, Yi-Feng
    Hsu, Tse-Chung
    Lin, Ching-Yon
    Shiea, Jentaie
    貢獻者: Chaoyang University of Technology
    National Sun Yat-sen Univ
    關鍵字: FD-ESI
    Quantitative
    Fermentation
    日期: 2008-07
    上傳時間: 2017-12-04 15:54:59 (UTC+8)
    摘要: Fermented dairy products are popular and nutritious foods due to the probiotics (lactic acid bacteria). The flavor produced during fermented milk products becomes an important topic for analytical chemists because they affect they affect thy tastes. Usually, fermentation procedure is monitrde by the change of pH and the flavor analysis is usually performed by GC or GC/MS. Since these instruments only detect nonpolar compound, some details of the flavor ingredient are not available. Herein, by using a FD-ESI source, we have developed a method for real-time quantitative detection of the flavor during fermentation. The measured targets are lactic acid lactic acid and acetic acid which are major components of the flavor and always make dramatic change of pH during the fermentation of milk.
    Iionization of the analyte in a FD-ESI source was achieved by reacting the gaseous analyte molecules with the charged solvent species generated by electrospray. The pure methanol was used for electrospray. A small amount of trifluoroacetic acid (10-9 M) was added into the ES solution as internal standard. The calibration curves were constructed by plotting the ratio of the lactic acid and acetic acid ion signals to the trifuoroacetic acid ion signal (peak height) versus the acid concentrations. Quantification of lactic acid and acetic acid in real sample (fermentation of milk) were then performed by this external standard method.
    There are three experimental parameters needed to be properly adjusted when using the FD-ESI to quantify the gaseous lactic and acetic acids: (1) relative position of the exit of the sample tube to the ES capillary tip; (2) flow rate of the nitrogen carrier gas; and (3) flow rate of the electrospray solution. The experimental results showed that the strongest ion signal would be obtained as the angle as the angle between the ES capillary and the sample tube is 60 degree and the distance between each other was 0.5-1.0 mm. The best distance between the ES capillary tip to the inlet of ion trap mass analyzer was found to be approximately 3.0~5.0 mm. The optimal condition was obtained when the flow rates of ES solution and nitrogen carrier gas were 2.5 uL/min and 400 c.c./min, respectively.
    關聯: 第五屆海峽化學、生物及材料研討會,起迄日:2008/07/21-2008/07/22,地點:嘉南藥理科技大學
    显示于类别:[藥理學院] 2008第五屆海峽化學、生物及材料研討會

    文件中的档案:

    档案 描述 大小格式浏览次数
    C09.pdf444KbAdobe PDF278检视/开启


    在CNU IR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈