Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/28568
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 18281/20508 (89%)
Visitors : 19516089      Online Users : 1396
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/28568


    题名: Evaluation and improvement of air quality in school public elevator
    作者: Hsu, Ching-Shan
    Huang, Da-Ji
    贡献者: 環境資源管理系
    关键词: Public elevator
    Bioaerosols
    Chlorine dioxide
    Disinfection
    日期: 2014-05
    上传时间: 2015-05-06 21:20:59 (UTC+8)
    出版者: Springer
    摘要: Public elevators are an essential requirement in modern high-rise buildings. However, the confined, crowded interior of an elevator provides an ideal breeding ground for all manners of biological aerosols. Consequently, when using an elevator at a university in Taiwan as the research target, this study performs an experimental investigation into the effectiveness of hand-sprayed gaseous chlorine dioxide as a disinfection agent. The air quality before and after disinfection is evaluated by measuring the bioaerosol concentrations of bacteria and fungi, respectively. The average background levels of bacteria and fungi before disinfection are found to be 635.7 +/- 469.6 and 1296.8 +/- 966.6 colony-forming unit (CFU)/m(3), respectively. Following disinfection, the bacteria and fungi concentrations reduced by an average of 35 and 25 %, respectively. The multivariate analysis of variance (MANOVA) results showed that the residual bacteria and fungi concentration levels were determined primarily by the number of individuals within the elevator and the elapsed time following disinfection. In general, the present results show that given a maximum of five individuals within the elevator, a disinfection schedule of once every 40 min is sufficient to reduce the bioaerosol concentrations of bacteria and fungi to the levels specified by the Taiwan Environmental Protection Agency (EPA).
    關聯: Environmental Monitoring and Assessment, v.186 n.5, pp.2941-2948
    显示于类别:[Dept. of Environmental Resources Management] Periodical Articles

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML2283检视/开启


    在CNU IR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback