|
English
|
正體中文
|
简体中文
|
全文筆數/總筆數 : 18074/20272 (89%)
造訪人次 : 4073354
線上人數 : 762
|
|
|
資料載入中.....
|
請使用永久網址來引用或連結此文件:
https://ir.cnu.edu.tw/handle/310902800/28560
|
標題: | Emissions of PCDD/Fs and PCBs during the Cold Start-up of Municipal Solid Waste Incinerators |
作者: | Guo, Chun-Jou Wang, Mao-Sung Lin, Sheng-Lun Mi, Hsiao-Hsuan Wang, Lin-Chi Chang-Chien, Guo-Ping |
貢獻者: | 環境工程與科學系 |
關鍵字: | Polychlorinated dibenzo-p-dioxins Polychlorinated dibenzofurans Polychlorinated biphenyls Municipal solid waste incinerators Cold start-up |
日期: | 2014-10 |
上傳時間: | 2015-05-06 21:20:42 (UTC+8) |
出版者: | Taiwan Assoc Aerosol Res-Taar |
摘要: | This study investigated the emissions of polychlorinated dibenzo-p-dioxins, dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) from 45-hr cold start-up operations (from the ambient temperature) of two municipal solid waste incinerators (MSWIs). Fifteen samples were collected during the whole process, while the sampling period was divided as follows: (1) the initial stage (25-250 degrees C); (2) the second stage (250-850 degrees C), and the final stage (850-1000 degrees C). The peak of total (PCDD/F + PCB) (WHO2005-TEQ) concentration occurred during the second stage of the cold start-up. This could because the temperature in the combustion chamber reached 295-359 degrees C, within the temperature window (250-450 degrees C) of PCDD/F reformation by de novo synthesis. However, both PCDD/F and PCB (WHO2005-TEQ) concentrations were still 2.8-3.8 times higher than the regulated standards in Taiwan 45 hours after the cold start-up began, demonstrating significant memory effects. Higher PCB/(PCDD/F + PCB) TEQ fractions were observed during the initial stage of cold start-up. This is probably due to the higher volatilities of memorized PCB-126 and -169 than PCDD/F congeners, thus making them more easily released into the flue gas. On the other hand, the total (PCDD/F + PCB) emissions during 45-hr cold start-up were estimated at 46-68 mg WHO2005-TEQ. The annual (PCDD/F + PCB) emissions from normal conditions are generally estimated by the normal operating emissions factor without the cold start-up. The normal annual (PCDD/F + PCB) emission rates of the two MSWIs were 70.7-101 mg WHO2005-TEQ, including once cold start-up emission, and these increased to 142-480 mg WHO2005-TEQ, up by 65-458%, if one to eight times of cold start-up were included. Therefore, reducing unnecessary start-ups could be more important with regard to controlling the PCDD/F and PCB emissions than only attempting to increase the pollutant removal efficiency in the steady operations of MSWIs. |
關聯: | Aerosol and Air Quality Research, v.14 n.6, pp.1593-U358 |
顯示於類別: | [環境工程與科學系(所)] 期刊論文
|
文件中的檔案:
檔案 |
描述 |
大小 | 格式 | 瀏覽次數 |
index.html | | 0Kb | HTML | 1586 | 檢視/開啟 |
|
在CNU IR中所有的資料項目都受到原著作權保護.
|