English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 18074/20272 (89%)
造訪人次 : 4072800      線上人數 : 889
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/27602


    標題: Managing Repeat Digital Radiography Images-A Systematic Approach and Improvement
    作者: Tzeng, Wen-Sheng
    Kuo, Kuang-Ming
    Liu, Chung-Feng
    Yao, Huan-Chung
    Chen, Chin-Yu
    Lin, Huang-Wei
    貢獻者: 資訊管理系
    關鍵字: Pacs
    Quality Assurance
    Digital Radiography
    Data Mining
    Repeat Analysis
    日期: 2012-08
    上傳時間: 2014-03-21 16:14:54 (UTC+8)
    出版者: Springer
    摘要: Repeat analysis is an important issue for improving image quality in the field of radiology. However, the required data for repeat analysis is not easy to collect, and the accuracy of the analysis results remains controversial. The main purpose of this study is to introduce a systematic approach and, with the assistance of information technology, to improve the accuracy of data collection methods and repeat analysis in a fully digital environment. Another purpose of the study was to reduce the human resources required to maintain image quality on a daily basis. The main participant in this study is the radiology department of a medical center in Taiwan. The hospital had previously implemented a Picture Archiving and Communication Systems (PACS), which was seamlessly integrated with Radiology Information Systems (RIS) and Hospital Information Systems (HIS). A comprehensive mechanism was built for repeat analysis. The analysis was primarily achieved through comparing the difference between the amount of accumulated digital radiography (DR) images and uploaded PACS images with data mining tools. Initially, the radiologic technologists seemed to be resistant to the new quality assurance mechanism, which introduce inaccuracy into the collected data. However, after introducing the improved standard operating procedures with the proposed approach for radiologic technologists, the number of DR images generated became optimal for comparison with the number of PACS images, which made this mechanism feasible. Furthermore, information was collected regarding the reasons for repeat images and was used for improving image quality. The results revealed that the new mechanism was both effective and accurate in the analysis of repeat images.
    關聯: Journal of Medical Systems, 36(4), 2697-2704
    顯示於類別:[資訊管理系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML2046檢視/開啟


    在CNU IR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋