Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/26952
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 18076/20274 (89%)
造访人次 : 4628229      在线人数 : 1109
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/26952


    標題: Managing Repeat Digital Radiography Images–A Systematic Approach and Improvement
    作者: Tzeng, Wen-Sheng
    Kuo, Kuang-Ming
    Liu, Chung-Feng
    Yao, Huan-Chung
    Chen, Chin-Yu
    Lin, Huang-Wei
    貢獻者: 資訊管理系
    日期: 2011-05
    上傳時間: 2013-09-28 16:25:28 (UTC+8)
    出版者: Springer
    摘要: Repeat analysis is an important issue for improving image quality in the field of radiology. However, the required data for repeat analysis is not easy to collect, and the accuracy of the analysis results remains controversial. The main purpose of this study is to introduce a systematic approach and, with the assistance of information technology, to improve the accuracy of data collection methods and repeat analysis in a fully digital environment. Another purpose of the study was to reduce the human resources required to maintain image quality on a daily basis. The main participant in this study is the radiology department of a medical center in Taiwan. The hospital had previously implemented a Picture Archiving and Communication Systems (PACS), which was seamlessly integrated with Radiology Information Systems (RIS) and Hospital Information Systems (HIS). A comprehensive mechanism was built for repeat analysis. The analysis was primarily achieved through comparing the difference between the amount of accumulated digital radiography (DR) images and uploaded PACS images with data mining tools. Initially, the radiologic technologists seemed to be resistant to the new quality assurance mechanism, which introduce inaccuracy into the collected data. However, after introducing the improved standard operating procedures with the proposed approach for radiologic technologists, the number of DR images generated became optimal for comparison with the number of PACS images, which made this mechanism feasible. Furthermore, information was collected regarding the reasons for repeat images and was used for improving image quality. The results revealed that the new mechanism was both effective and accurate in the analysis of repeat images.
    關聯: Journal of Medical Systems 36(4), pp.2697-2704
    显示于类别:[資訊管理系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML1958检视/开启


    在CNU IR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈