Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/24370
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 18034/20233 (89%)
Visitors : 23745873      Online Users : 705
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    CNU IR > Chna Nan Annual Bulletin > Vol.14 (1988) >  Item 310902800/24370
    Please use this identifier to cite or link to this item: https://ir.cnu.edu.tw/handle/310902800/24370


    Title: Removing Humic Acid Complexes of Cr(VI),Pb(II) and Zn(II) from Natural Water by Coagulation Process
    以混凝程序去除自然水中鉻、鉛、鋅錯合物之研究
    Authors: J.S.Huang
    K.C.Yu
    Contributors: 成功大學環境工程研究所
    嘉南藥專工業安全衛生科
    Keywords: Heavy metals
    Humic acid
    Natural water
    Equilibrium dialysis
    Coagulation
    重金屬
    腐植酸
    自然水
    平衡滲析
    混凝
    Date: 1988
    Issue Date: 2011-10-06 11:21:16 (UTC+8)
    Abstract: The objectives of this study were to inquire the feasibility of the removal of Cr(VI), Pb(II), Zn(H) by coagulation process and to determine the effect of the humic acid on the removal of the aforesaid heavy metals. The results indicated while the removal of Cr(VI) using coagulant of ferrous sulfate was very effective, using alum and ferric chloride was ineffective. The removal of Pb(II) and Zn(II) using alum and ferric chloride was very effective and the higher the pH the better the removal efficiency. The removal of Cr(VI) using alum could be benefited by the input of humic acid. However, the removal of Pb(II) could be obstructed when the humic acid was not completely removed by coagulation. As the pH was greater than 8, the removal of Zn(H) was impeded by the input of the humic acid. In contrast, as the pH was less than 8, the removal of Zn(II) was improved.
    混凝沉澱程序是給水廠中對濁度及色度去除的重要處理單元之一,本研究主要係藉此一處理程序來探討對重金屬鉻、鉛、鋅之去除效果以及腐植酸對其處理效果之影響。試驗結果發現硫酸亞鐵對六價鉻之去除效果極佳,硫酸鋁及氯化鐵對六價鉻之去除效果則很差。而氯化鐵及硫酸鋁對二價鉛及二價鋅之去除效果則很好,且隨pH值的增加而愈佳。腐植酸有助硫酸鋁去除六價鉻;而對於鉛,則在腐植酸未完全去除前,對鉛之去除有所妨礙,但當腐植酸可完全被去除時,則腐植酸對鉛之去除甚有助益。腐植酸之pH值大於8時,妨礙了鋅之去除,然在pH值小於8時, 則能增進鋅之去除。平衡滲析試驗結果發現六價鉻、二價鉛、二價鋅與腐植酸錯合程度係隨pH值升高而增加,三者錯合能力大小依序為二價鉛、二價鋅、六價鉻。