Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/24223
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 18074/20272 (89%)
Visitors : 4078090      Online Users : 1213
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: https://ir.cnu.edu.tw/handle/310902800/24223


    Title: The LC/MS2 Detection Method of Chloroamphetamine
    Authors: Yu-Ling Cheng (鄭郁陵)
    Der-Seang Lee (李得响)
    Su-Jung Chen (陳素容)
    Tzu-yen Ku (辜子嫣)
    Jia-Der Fang (方嘉德)
    Date: 2011
    Issue Date: 2011-06-23 14:57:15 (UTC+8)
    Abstract: In recent years, the problem of abuse drugs is day by day serious, especially to evade the legal punishment responsibility, some new types of abuse drugs appear unceasingly. Taking these abuse drugs, not only polices cannot arrest them, but the harm to human body is worse than the original abuse drug, which chloroamphetamine is a typical example. Therefore, we need to develop a detection method that can detect chloroamphetamine. The reseaearch is aimed at chloroamphetamine to develop LC/MS2 detection method by ESI-IT detection mode. In this analysis method, we adopted operation method that used flunitrazepam (FM2) as internal standard. First, obtained chloroamphetamine and flunitrazepam's main daughter ions after CID reaction, the m/z values respectively are: flunitrazepam (314.2→268.1), chloroamphetamine (169.9→152.7). Then we adopted 0.01% TFA aqueous solution and 0.01% TFA methanol solution as two solvents of LC gradient elution process. At the same time, we used C18 analytical column as separation column to operate ion-paired chromatographic separation. This analysis result shows that when using flunitrazepam as internal standard to quantify chloroamphetamine, the calibration curve has good linearity. The calibration curve between 60 to 1000 ppb is Y = 0.0063X + 0.2475, R2 = 0.9955, compared with the data of previously using the same internal standard to detect methamphetamine is, the calibration curve between 2 to 60 ppb is Y = 0.0582X + 0.1362, R2 = 0.9888. For all of these results, we can find when increased a chlorine substituting group and lower the polarity of compound , the result for using reverse chromatographic separation and the electrospray ionization effect of ESI have apparently influence, so it leads the dynamic linear range raising a lot. But if this LC/MS2 detection method had collocated with preconcentration column to operate the operation mode of low concentration sample concentrated process, it would also reduce the concentration range of detection limit.
    Relation: 2011年台俄有機、藥物與生物化學交流暨藥物化學研討會,起迄日:2011/04/06~2011/04/05,地點:溪頭台大實驗林
    Appears in Collections:[Pharmacy and Science] 2011 Taiwanese-Russian Organic, Medicinal and Bio Chemistry Interactions & PST Medicinal Chemistry Symposium
    [Dept. of Pharmacy] Proceedings

    Files in This Item:

    File Description SizeFormat
    pp-07.pdf94KbAdobe PDF488View/Open


    All items in CNU IR are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback