Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/24222
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 18074/20272 (89%)
Visitors : 4076206      Online Users : 1250
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: https://ir.cnu.edu.tw/handle/310902800/24222


    Title: The LC/MS2 Detection Methods of Aminelike Abuse Drugs
    Authors: Yu-Ling Cheng (鄭郁陵)
    Der-Seang Lee (李得响)
    Su-Jung Chen (陳素容)
    Tzu-yen Ku (辜子嫣)
    Jia-Der Fang (方嘉德)
    Date: 2011
    Issue Date: 2011-06-23 14:57:14 (UTC+8)
    Abstract: In recent years, the problem of abuse drugs is day by day serious, and the youth come into contact with the opportunities of drug abuse have also increased enormously. In order to deter the phenomenon of abuse drugs, and tracking the user's drug addiction histories, therefore, we need to develop a detection method that can detect both low concentration of all common abuse drugs and their physiological metabolites, and also provided with accurate and rapid advantages. The research is aimed at class one to three of amines abuse drugs such as cocaine (Coc), methamphetamine (MA), flunitrazepam (FJV12), ketamine (K), ketamine' s physiological metabolites, norketamine (NK) and dehydronorketamine (DHNK) and so on each kind of compounds to develop LC/MS2 detection method by ESI-IT detection mode. In this analysis method, we adopted operation method that used mutual as internal standard. First, obtained these compounds' main daughter ions after CID reaction, the m/z values respectively are: cocaine (304.0→182.0), methamphetamine (150.1→119.0), flunitrazepam (314.2→268.1), ketamine (238.0→206.9), norketamine (223.9→206.9), and dehydronorketamine (222.0→204.9). Then we adopted 0.01% TFA aqueous solution and 0.01% TFA methanol solution as two solvents of LC gradient elution process. At the same time, we used C18 analytical column as separation column to operate ion-paired chromatographic separation. When quantify the components of the solutions, we used the ratio of peak area as quantitative factor of analysis operation mode. This analysis results show that when using flunitrazepam as internal standard to quantify cf cocaine,methamphetamine, ketamine, norketamine, and dehydronorketamine and so on each kind of compounds, and used ketamine as internal standard to quantify flunitrazepam, the calibration curves all have good linearity. And if this LC/MS2 detection method had collocated with preconcentration column to operate the operation mode of low concentration sample concentrated process, it would also reduce the concentration range of detection limit.
    Relation: 2011年台俄有機、藥物與生物化學交流暨藥物化學研討會,起迄日:2011/04/06~2011/04/05,地點:溪頭台大實驗林
    Appears in Collections:[Pharmacy and Science] 2011 Taiwanese-Russian Organic, Medicinal and Bio Chemistry Interactions & PST Medicinal Chemistry Symposium
    [Dept. of Pharmacy] Proceedings

    Files in This Item:

    File Description SizeFormat
    pp-06.pdf97KbAdobe PDF551View/Open


    All items in CNU IR are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback