Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/22218
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 18076/20274 (89%)
造访人次 : 4614545      在线人数 : 1292
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/22218


    標題: A surface acoustic wave sensor modified from a wireless transmitter for the monitoring of the growth of bacteria.
    作者: Ku-Shang Chang
    Chen-Kai Chang
    Chien-Yuan Chen
    貢獻者: 食品科技系
    關鍵字: Surface acoustic wave
    SAW
    Escherichia coli
    Bacterial growth
    日期: 2007-07
    上傳時間: 2010-01-15 10:18:50 (UTC+8)
    摘要: This work presents a novel surface acoustic wave (SAW) sensor for the measurement of the microbial count in a biological culture. The signal translation interface of the sensor was modified using a common commercial wireless SAW transmitter design. A pair of conductive electrodes was inserted in a 314.5 MHz SAW stabilized oscillator of the transmitter. Measurements were made by placing the electrodes within the culture solution of interest and measured the time required to identify readily detectable frequency changes (detection time, DT). The change of frequency was caused by the impedance change of the microbial metabolism. The calibration curve of detection times against density of Escherichia coli shows a linear correlation coefficient (R2 = 0.924) over the range of 102 to 107 cells/mL. A sample that contains 102 cells/mL of E. coli required a detection times (DT) of 7 h, shorter than was required using instruments based on conventional conductance methods. The proposed ultra high frequency SAW sensor (314.5 MHz) shows a large total frequency change and gives a sharp inflexion at the DT but possesses the same stability compared with that of low frequency serial piezoelectric quartz crystal (PQC) sensor for the measurement of bacteria concentration. This sensor platform enabled real time monitoring of bacterial growth within a sealed opaque container. This sensor is potentially applicable to a remote query wireless measurement in hazardous environments when a suitable antenna device is adapted.
    關聯: Sensors and Actuators B: Chemical 125 (1): p.207-213
    显示于类别:[ 食品科技系 ] 期刊論文

    文件中的档案:

    档案 大小格式浏览次数
    0KbUnknown2071检视/开启


    在CNU IR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈