Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/21378
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 18076/20274 (89%)
Visitors : 4614574      Online Users : 1282
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    CNU IR > Chna Nan Annual Bulletin > No.29 (2003) >  Item 310902800/21378
    Please use this identifier to cite or link to this item: https://ir.cnu.edu.tw/handle/310902800/21378


    Title: 以多元迴歸分析模式建立台灣地區垃圾發熱量本土化經驗公式之研究
    Establishing the Empirical Equations of Lower Heating Value of Municipal Solid Waste by Multiple Regression Model in Taiwan
    Authors: 張翊峰
    林健榮
    錢紀銘
    洪春守
    Contributors: 環境工程與科學系
    Keywords: 垃圾物理組成
    發熱量經驗推估公式
    多元迴歸分析
    Physical combustible component
    Local empirical equations of lower heating value
    Multiple regression model
    Date: 2003
    Issue Date: 2009-06-11 13:32:41 (UTC+8)
    Abstract: 本研究以台灣地區全省及高雄市垃圾採樣分析之實測資料共150組數據,分析每組垃圾之濕基及乾基物理組成分包括紙類、纖維布類、木竹、廚餘類、塑膠類、皮革橡膠類及其他類等可燃性成分比例配合實測之低位發熱量,以多元迴歸統計模式建立以垃圾濕基物理組成或乾基物理組成推估垃圾發熱量之經驗公式,並將公式所推導之推估值與實測資料進行比對,以評估本研究所推導公式應用的可行性。
    本研究結果顯示垃圾發熱量高低與濕基物理組成中皮革含量多寡關係最為密切,其次為塑膠、纖維布、紙類、廚餘類、木竹類及其他類,模式之判定係數R2等於0.994,顯示本研究所推導之以濕基物理組成或乾基物理組成推估垃圾發熱量之經驗公式為合宜的統計推估模式。另將本研究所推估之結果相較現行之三成分或物理組成模型或元素分析推估模式比較,顯示本研究推導之經驗公式適用性與精確度為模式中最為精準者,在台灣地區極具實用價值,其成果有益於台灣地區都市焚化廠以簡單之濕基物理組成分類或乾基組成,即可預判進入焚化廠垃圾發熱量品質之優劣,據以調整焚化爐之操作條件。此外,本結果亦顯示都市垃圾估計塑膠類乾基組成降低1%,每公斤垃圾將損失62 kcal左右之熱值,此一結果可提供目前環保署所推動之塑膠限用政策,研擬對焚化爐進場垃圾低位發熱量變化之政策參考。
    This study employed the multiple regression model to construct a set of local empirical equations of lower heating value (LHV) for municipal solid waste (MSW) in Taiwan. Solid waste samples were gathered from different cities and counties during the period of 2001-2002 in Taiwan. First, the LHV and physical combustible component contents of each sample are examined for the establishment of the regression model. Contents of combustible physical component were then used to match the equation of lower heating value, and the multiple regression analysis was applied to establish the empirical equations for LHV. Finally, another sets of data obtained from another research were used to evaluate the feasibility of the LHV prediction model in this work.
    Two equations, the dry-basis and wet-basis equations which were obtained based on the dry-basis and wet-basis, are presented in this study. The correlation coefficients of multiple determination for the dry-basis equation and the wet-basis equation are 0.994 and 0.986, respectively. Both equations are fitted well by the statistical. Furthermore, if we compare these two empirical equations with other equations presented in the literatures, the Mean Absolute Percentage Error (MAPE) of these two equations is lower obviously than those of other equations. These results reveal that these empirical equations obtained in the present paper are applicable for the determination of LHV of MSW economically by physical component, in place of bomb calorimeter.
    Relation: 嘉南學報(科技類)29期:p.193-201
    Appears in Collections:[Chna Nan Annual Bulletin] No.29 (2003)
    [Dept. of Environmental Engineering and Science (including master's program)] Periodical Articles

    Files in This Item:

    File Description SizeFormat
    v29_193_201.pdf70KbAdobe PDF1143View/Open


    All items in CNU IR are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback