Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/21121
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 18034/20233 (89%)
造访人次 : 23763122      在线人数 : 770
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/21121


    標題: Fe+3樹脂觸媒/過氧化氫系統應用於受五氯酚污染地下水之氧化作用
    Catalytic Oxidation of Pentachlorophenol in Groundwater by Fe+3-Resin Catalyst/H2O2 Oxidation System
    作者: 劉瑞美
    陳世雄
    洪睦雅
    王睿智
    林孟歆
    蘇琼惠
    吳恬宜
    貢獻者: 環境工程與科學系
    環境資源管理系
    關鍵字: 五氯酚
    Fe+3-樹脂觸媒
    異相氧化反應
    地下水
    毒性
    Pentachlorophenol
    Fe-resin catalyst
    Heterogeneous oxidation
    Groundwater
    Toxicity
    日期: 2006
    上傳時間: 2009-04-24 13:50:40 (UTC+8)
    摘要: 本研究利用含浸氯化鐵的樹脂觸媒充當異相催化反應催化劑,以0.5 M的FeCl3 ‧6H2O含浸濃度,0.5%(w/v)樹脂觸媒劑量、0.1M的H2O2劑量、控制起始pH值為7與反應溫度80℃進行五氯酚氧化程序,並進行重複回收樹脂觸媒之可行性評估,經3次回收使用的樹脂觸媒仍具有高的五氯酚氧化效率,預期可降低五氯酚水相污染整治復育之經費。利用Microtox生物毒性測試,在最佳操作條件下五氯酚經本系統氧化40分鐘後其毒性偵測值為0,在模擬地下水中氧化處理五氯酚,隨地下水性質之改變,Fe+3樹脂觸媒/H2O2系統之氧化效率略有不同,但仍可成功且快速的氧化地下水中五氯酚。
    The object of this study was focusing on the oxidation treatment of pentachlorophenol (PCP) utilizing the heterogeneous resin catalyst prepared by the immersing method. The treatment efficiency and conditions was discussed in a batch reactor. In order to investigate the feasibility of recycling Fe+3-resin catalyst, the batch condition was set as 0.5% (w/v) catalyst dosage, 0.1 M H2O2, pH 7, and reaction temperature 80℃. The used catalysts were recovered after oxidation reaction and were reused in the oxidation of PCP in aqueous solution for four successive times. The results showed that the same Fe+3-resin could be reused for at least three cycles of PCP oxidation in aqueous solution. Moreover, it also indicated that the toxicity of oxidation product was almost decomposed after 40 minutes oxidation. The high efficiency of oxidation and toxicity test showed that the Fe+3 resin/H2O2 system would be the referee of polluted groundwater remediation processes.
    關聯: 嘉南學報(科技類) 32期:p.36-44
    显示于类别:[嘉南學報] 32 期 (2006)
    [環境工程與科學系(所)] 期刊論文
    [環境資源管理系(所)] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    v32_36_44.pdf797KbAdobe PDF648检视/开启


    在CNU IR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈