Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/31586
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 18034/20233 (89%)
造访人次 : 23621189      在线人数 : 608
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/31586


    標題: Assessment of Indoor Bioaerosols in Public Spaces by Real-Time Measured Airborne Particles
    作者: Huang, Hsiao-Lin
    Lee, Mei-Kuei
    Shih, Hao-Wun
    貢獻者: Chia Nan Univ Pharm & Sci, Dept Occupat Safety & Hlth
    關鍵字: Suspended particulate
    Biohazard
    Aerosol
    Indoor air
    PM2.5
    日期: 2017-15
    上傳時間: 2018-11-30 15:49:15 (UTC+8)
    出版者: Taiwan Assoc Aerosol Res-Taar
    摘要: Humans spend a considerable amount of time indoors, and indoor biological airborne pollutants may harm human health. Active bioaerosol samplers and conventional microbiological culture methods, which are widely applied in studies of airborne microbial contamination, are not only unable to perform continuous monitoring over long periods, but are also time-consuming and expensive. In order to rapid assess indoor airborne microbial contamination, multiple linear regression models were constructed by statistically analyzing the measured bioaerosol samples and the real-time measured mass and number concentrations of airborne particles using a direct reading instrument from 43 air-conditioned public spaces. There were significant positive correlations of indoor airborne bacterial and fungal concentrations with indoor size-segregated particle mass and number concentrations. The predictive power of the model was sufficient for predicting indoor bacterial concentrations from the indoor and outdoor size-segregated particle number concentrations as independent variables. Particle number concentration outperforms particle mass concentration as an independent variable in predicting indoor bioaerosol concentrations. The prediction model for indoor bacterial bioaerosol levels constructed in this study could facilitate a rapid assessment of potential airborne bacterial contamination via the simple and feasible measurement of particle number concentration, thus helping to improve the management and maintenance of indoor air quality.
    關聯: Aerosol and Air Quality Research, v.17, n.9, pp.2276-2288
    显示于类别:[職業安全衛生系(含防災所)] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    aaqr.2017.02.0089.pdf350KbAdobe PDF515检视/开启
    aaqr.2017.02.0089.pdf350KbAdobe PDF325检视/开启
    index.html0KbHTML1453检视/开启


    在CNU IR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈