Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/31036
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 18034/20233 (89%)
造访人次 : 23631525      在线人数 : 715
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/31036


    標題: Design of wireless multi-parameter monitoring system for oral feeding of premature infants
    作者: Wang, Yu-Lin
    Kuo, Hsing-Chien
    Wang, Lin-Yu
    Ko, Mei-Ju
    Lin, Bor-Shyh
    貢獻者: Chi Mei Med Ctr, Dept Rehabil
    Natl Chiao Tung Univ, Inst Imaging & Biomed Photon
    Chia Nan Univ Pharm & Sci, Dept Sports Management
    Chia Nan Univ Pharm & Sci, Dept Childhood Educ & Nursery
    關鍵字: Premature infant
    Oral feeding
    Wireless multi-parameter monitoring system
    Sucking-swallowing-respiratory activities
    Heart rate variability
    sounds
    日期: 2016-07
    上傳時間: 2018-01-18 11:40:19 (UTC+8)
    出版者: Springer Heidelberg
    摘要: Premature infants often cannot successfully and coordinately complete their oral feeding. Mature sucking, swallowing, and respiration activities are crucial indicators for the survival of newborn infants. Due to the vulnerability and unobvious muscle activities of premature infants, current clinical care givers mainly depend on the subjective behavioral observation of infants during oral feeding. There is still lack of an integrated oral feeding monitoring system to objectively and quantifiably monitor the related physiological parameters of premature infants. In this study, a wireless multi-parameter monitoring system for oral feeding of premature infants was proposed to monitor the sucking-swallowing-respiratory activities and the heart rate variability to provide quantitative indices of oral feeding. Here, a novel sucking pressure sensing module was also developed to monitor the premature infant's sucking pressure under oral feeding to avoid the immersion influence of milk. The experimental results showed that the proposed system detected the related physiological parameters of premature infants during oral feeding effectively and may provide an objective clinical evaluation tool for oral feeding ability and safety of premature infants in the future.
    關聯: Medical & Biological Engineering & Computing, v.54 n.7, pp.1061-1069
    显示于类别:[嬰幼兒保育系] 期刊論文
    [運動管理系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML1555检视/开启


    在CNU IR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈