Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/29591
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 18034/20233 (89%)
Visitors : 23763122      Online Users : 770
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: https://ir.cnu.edu.tw/handle/310902800/29591


    Title: In Situ Test of School Buildings Retrofitted with External Steel-Framing Systems
    Authors: Shih, C. T.
    Chu, S. Y.
    Liou, Y. W.
    Hsiao, F. P.
    Huang, C. C.
    Chiou, T. C.
    Chiou, Y. C.
    Contributors: 職業安全衛生系
    Keywords: School buildings
    External steel-framing systems
    In situ push-over test
    Seismic capacity assessment
    Concrete and masonry structures
    Date: 2015-01
    Issue Date: 2016-04-19 19:01:19 (UTC+8)
    Publisher: Asce-Amer Soc Civil Engineers
    Abstract: In situ push-over experiments and analytical assessments were conducted in this study to investigate the seismic capacity of RC school buildings at the Guan-miao Elementary School in Tainan City, Taiwan. Both prototype and external steel-framing specimens were constructed and compared. Reinforcements with steel channels were adhered to the captive columns and their adjacent beams in the weak direction, to retrofit the school building through the creation of external steel-framing systems. The design and construction procedures of the beam-column connection are introduced, as well as detailed drawings of the column-base anchorage system, both of which are key to the effects of the proposed retrofitting method. The experimental results show that the steel-framing system can be firmly bonded to the retrofitted specimen, providing continuous stress transference from the beam-column joints to the steel channels. The failure mode of the retrofitted captive columns was shifted from shear failure, as seen with the prototype specimen, to flexural-shear failure, with the retrofitted one. Both the experimental and analytical results show the following: The maximum total base shear strength increases 2.11 times, the total enclosed area of the stored energy increases 2.20 times, and ductility capacity increases 1.31 times. The external steel-framing systems proposed in this work can thus effectively enhance the base shear strength and the ductility of the specimens. (C) 2014 American Society of Civil Engineers.
    Relation: Journal of Structural Engineering, v.141 n.1 S1, Article ID D4014002
    Appears in Collections:[Dept. of Occupational Safety] Periodical Articles

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML1600View/Open


    All items in CNU IR are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback