English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 18034/20233 (89%)
造訪人次 : 23695198      線上人數 : 520
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: https://ir.cnu.edu.tw/handle/310902800/24223


    標題: The LC/MS2 Detection Method of Chloroamphetamine
    作者: Yu-Ling Cheng (鄭郁陵)
    Der-Seang Lee (李得响)
    Su-Jung Chen (陳素容)
    Tzu-yen Ku (辜子嫣)
    Jia-Der Fang (方嘉德)
    日期: 2011
    上傳時間: 2011-06-23 14:57:15 (UTC+8)
    摘要: In recent years, the problem of abuse drugs is day by day serious, especially to evade the legal punishment responsibility, some new types of abuse drugs appear unceasingly. Taking these abuse drugs, not only polices cannot arrest them, but the harm to human body is worse than the original abuse drug, which chloroamphetamine is a typical example. Therefore, we need to develop a detection method that can detect chloroamphetamine. The reseaearch is aimed at chloroamphetamine to develop LC/MS2 detection method by ESI-IT detection mode. In this analysis method, we adopted operation method that used flunitrazepam (FM2) as internal standard. First, obtained chloroamphetamine and flunitrazepam's main daughter ions after CID reaction, the m/z values respectively are: flunitrazepam (314.2→268.1), chloroamphetamine (169.9→152.7). Then we adopted 0.01% TFA aqueous solution and 0.01% TFA methanol solution as two solvents of LC gradient elution process. At the same time, we used C18 analytical column as separation column to operate ion-paired chromatographic separation. This analysis result shows that when using flunitrazepam as internal standard to quantify chloroamphetamine, the calibration curve has good linearity. The calibration curve between 60 to 1000 ppb is Y = 0.0063X + 0.2475, R2 = 0.9955, compared with the data of previously using the same internal standard to detect methamphetamine is, the calibration curve between 2 to 60 ppb is Y = 0.0582X + 0.1362, R2 = 0.9888. For all of these results, we can find when increased a chlorine substituting group and lower the polarity of compound , the result for using reverse chromatographic separation and the electrospray ionization effect of ESI have apparently influence, so it leads the dynamic linear range raising a lot. But if this LC/MS2 detection method had collocated with preconcentration column to operate the operation mode of low concentration sample concentrated process, it would also reduce the concentration range of detection limit.
    關聯: 2011年台俄有機、藥物與生物化學交流暨藥物化學研討會,起迄日:2011/04/06~2011/04/05,地點:溪頭台大實驗林
    顯示於類別:[藥理學院] 2011年台俄有機、藥物與生物化學交流暨藥物化學研討會
    [藥學系(所)] 會議論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    pp-07.pdf94KbAdobe PDF451檢視/開啟


    在CNU IR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋