Chia Nan University of Pharmacy & Science Institutional Repository:Item 310902800/21402
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 18034/20233 (89%)
Visitors : 23759614      Online Users : 772
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    CNU IR > Chna Nan Annual Bulletin > No.29 (2003) >  Item 310902800/21402
    Please use this identifier to cite or link to this item: https://ir.cnu.edu.tw/handle/310902800/21402


    Title: 利用離子交換樹脂處理含貴金屬金電鍍廢液及菌垢問題初探
    A Preliminary Study on Precious Metal Recovery by Ion Exchange Resin from Electroplating Wastewater and Bio-Fouling Problem
    Authors: 張家源
    吳宗勳
    王亭雯
    陳必祥
    Contributors: 環境工程與科學系
    Keywords: 離子交換樹脂
    貴金屬
    吸附模式
    薄膜前處理
    菌落數
    Ion exchange resin
    Precious metal
    Isotherm
    Membrane pretreatment
    Total number of bacteria
    Date: 2003
    Issue Date: 2009-06-12 13:08:25 (UTC+8)
    Abstract: 離子交換樹脂法為一成熟且商業化之高級處理技術,已廣泛應用於淨水及電鍍廢水處理上,本研究選用離子交換樹脂來回收電鍍廢液中之有價金屬,本研究以市售七種(A,B,C,D,E,F,G)不同之離子交換樹脂吸附電鍍廢液溶液中的金,主要探討的部份有批次吸附之效能、等溫平衡關係式及廢水之薄膜預過濾處理對吸附效能之影響。就批次吸附方面,探討不同樹脂對於金吸附效率的差異,進而從中挑選出對於吸附金比較有利之樹脂,實驗結果顯示B與D對廢液中金的吸附效果較佳,其餘以A、C、E、F次之,四者之吸附能力相差不多,惟樹脂G之吸附效能最差。在等溫平衡實驗方面,經由恆溫吸附實驗結果得知,除了G樹脂以外,其他樹脂之恆溫吸附行為可符合Langmuir和Freundlich等溫吸附模式,但以Freundlich模式符合度較佳。在前處理方面
    ,實驗結果顯示,掃流式薄膜前處理方法對提升樹脂吸附電鍍廢液中金之效能助益不大。未稀釋之電鍍槽原液可抑制細菌之生長,而低金濃度電鍍水洗水原液無法抑制細菌之生長。電鍍水洗水廢液經薄膜預處理後,不論過濾液與未過濾液均有菌落數產生,惟過濾液所培養出之菌落數較未過濾液為少。
    In this study, the commercial resin was used in the recovery and separation of Au from electroplating wastewater. The present investigation focuses on the batch equilibrium, the related theoretical modeling using the appropriate ion exchange models and the effect of membrane pretreatment on the recovery of Au. Seven commercial resins were used in the present study. Various isotherms, including Langmuir and Freundlich types, were adopted and tested to model the equilibrium ion exchange of the system. Regression analysis experimental data also confirms that the behavior
    observed in this study can be described by Freundlich isothermal adsorption equation. The effect of cross-flow microfiltration pretreatment was not significantly on the enhancement of adsorption capacities. The results also showed that the raw electroplating wastewater could inhibit the growth of bacteria but the diluted electroplating solution didn’t. Besides, the pretreatment of membrane filtration has a significant effect on the cut-off of the total number of bacteria in the electroplating wastewater.
    Relation: 嘉南學報(科技類)29期:p.236-247
    Appears in Collections:[Chna Nan Annual Bulletin] No.29 (2003)
    [Dept. of Environmental Engineering and Science (including master's program)] Periodical Articles

    Files in This Item:

    File Description SizeFormat
    v29_236_247.pdf87KbAdobe PDF683View/Open


    All items in CNU IR are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback